EFFICIENCY KING S2
Keywords:
- Product Description
-
Performance King S2 Product Advantages
System efficiency up to 92.9% @0.25°C
A 1 MWh power plant generates over 300,000 yuan in additional revenue throughout its lifecycle.
Pioneering in 3 major industries
Dual-Engine Air-Liquid Intelligent Cooling Technology
Based on different temperature environments, the cooling mode is intelligently selected to achieve minimum power loss, improving the overall system efficiency by 1-2% over the entire year.
Stacked Light Energy Storage Technology
Innovatively, we’ve added photovoltaic power generation to the site, further reducing energy storage losses and boosting the overall system’s round-trip efficiency by 0.5–1% annually.
AI All-Time Equalization
By collecting data from each battery cell and leveraging large-scale AI domain models for big data analytics, we can autonomously optimize charging and discharging strategies in conjunction with environmental conditions.
3 Major Upgrades
Newly upgraded SiC-PCS
High-efficiency third-generation SiC semiconductor—silicon carbide core components with a maximum conversion efficiency of 99%.
Highest energy density
Energy density: 198 Wh/m²; area footprint reduced by 16%; lower delivery costs.
Multiple layers of security protection
Multi-level fire prevention and all-weather alerts, high-strength armored cabinet, and highly protective Seagull system.
Performance King S2 Specifications
Battery-side parameters
Battery type
LFP
Battery of Life (BOL)
261kWh
Battery voltage range
650~949V
AC-side parameters
Rated power on the AC side
130kW
100kW
Rated grid voltage
380V/400V
Grid voltage range
-15% to 10%
Rated grid frequency
50/60Hz
Power grid frequency range
±10%
Access method
Three-phase three-wire / Three-phase four-wire
Total Harmonic Distortion (THDi) – Maximum
3% (rated power)
Power factor range
-1 to 1
System parameters
Dimensions (width × height × depth)
980×2300×1350mm
Weight
≤2500kg
Maximum cycle efficiency
92.9%
Temperature control method
Dual-engine air-liquid intelligent cooling
Operating temperature range
-30~50℃ (>45℃ derating)
Operating humidity range
0–100% RH (no condensation)
Maximum operating altitude
4000m (>2000m derating)
Fire system configuration
Smoke detectors, heat detectors, aerosol systems, water-based fire suppression
System communication interface
RS-485/Ethernet
System communication protocol
Modbus RTU/Modbus TCP
Protection level
IP55
Corrosion resistance grade
C3/C5
Certification standards
GB/T 36276; GB 44240